Product Overview

Category

The P51-500-A-I-MD-5V-000-000 belongs to the category of precision sensors.

Use

It is used for measuring and monitoring pressure in various industrial applications.

Characteristics

  • High precision measurement
  • Compact design
  • Wide operating temperature range
  • Robust construction for industrial environments

Package

The sensor is typically packaged in a protective casing with appropriate connectors for easy integration into different systems.

Essence

The essence of the P51-500-A-I-MD-5V-000-000 lies in its ability to provide accurate and reliable pressure measurements in challenging industrial settings.

Packaging/Quantity

The sensor is usually available as a single unit, packed securely to prevent damage during transportation and storage.

Specifications

  • Pressure Range: 0-500 psi
  • Output: 5V
  • Accuracy: ±1%
  • Operating Temperature: -40°C to 125°C
  • Electrical Connection: Integral cable or connector options

Detailed Pin Configuration

The detailed pin configuration of the P51-500-A-I-MD-5V-000-000 includes: - Pin 1: Power supply - Pin 2: Ground - Pin 3: Signal output

Functional Features

  • High accuracy and repeatability
  • Built-in overpressure protection
  • Long-term stability
  • Compatibility with various media including liquids and gases

Advantages

  • Precise and reliable pressure measurements
  • Suitable for harsh industrial environments
  • Easy integration into existing systems
  • Low power consumption

Disadvantages

  • Limited pressure range compared to some other sensors
  • May require additional calibration for specific applications

Working Principles

The P51-500-A-I-MD-5V-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, resulting in a proportional change in electrical resistance. This change is then converted into an electrical signal representing the measured pressure.

Detailed Application Field Plans

The P51-500-A-I-MD-5V-000-000 is widely used in various industries such as: - Automotive - Aerospace - Oil and gas - Industrial machinery - HVAC systems

Its applications include pressure monitoring in hydraulic systems, pneumatic equipment, process control, and more.

Detailed and Complete Alternative Models

Some alternative models to the P51-500-A-I-MD-5V-000-000 include: - P51-100-A-I-MD-5V-000-000 (100 psi range) - P51-1000-A-I-MD-5V-000-000 (1000 psi range) - P51-2500-A-I-MD-5V-000-000 (2500 psi range)

These models offer different pressure ranges to suit specific application requirements.

In conclusion, the P51-500-A-I-MD-5V-000-000 precision sensor provides accurate and reliable pressure measurements in demanding industrial environments, making it a valuable component in various applications across different industries.

[Word count: 455]

Senaraikan 10 soalan dan jawapan biasa yang berkaitan dengan aplikasi P51-500-A-I-MD-5V-000-000 dalam penyelesaian teknikal

  1. What is the P51-500-A-I-MD-5V-000-000?

    • The P51-500-A-I-MD-5V-000-000 is a pressure transducer commonly used in technical solutions to measure and transmit pressure readings.
  2. What are the key features of the P51-500-A-I-MD-5V-000-000?

    • The key features include a 4-20 mA output, a 0-500 psi pressure range, a 5V power supply, and a rugged design suitable for various industrial applications.
  3. How do I calibrate the P51-500-A-I-MD-5V-000-000?

    • Calibration typically involves applying a known pressure to the transducer and adjusting the output signal to match the expected value using a calibration device or software.
  4. What are the typical applications for the P51-500-A-I-MD-5V-000-000?

    • Common applications include hydraulic systems, pneumatic systems, industrial machinery, and process control where accurate pressure measurement is essential.
  5. Can the P51-500-A-I-MD-5V-000-000 be used in hazardous environments?

    • Yes, the P51-500-A-I-MD-5V-000-000 is available with intrinsically safe options, making it suitable for use in hazardous locations.
  6. What is the temperature range for the P51-500-A-I-MD-5V-000-000?

    • The standard temperature range is -40°C to 85°C (-40°F to 185°F), but extended temperature ranges may be available for specific applications.
  7. Does the P51-500-A-I-MD-5V-000-000 require any special mounting considerations?

    • It is recommended to mount the transducer in a location that minimizes exposure to vibration, shock, and extreme temperatures to ensure accurate and reliable performance.
  8. How can I troubleshoot issues with the P51-500-A-I-MD-5V-000-000?

    • Troubleshooting may involve checking the power supply, verifying the wiring connections, inspecting for damage, and ensuring proper environmental conditions for operation.
  9. Is the P51-500-A-I-MD-5V-000-000 compatible with different communication protocols?

    • Some models may offer compatibility with various communication protocols such as Modbus, HART, or Profibus, depending on the specific configuration.
  10. What maintenance is required for the P51-500-A-I-MD-5V-000-000?

    • Regular maintenance may include periodic calibration checks, inspection for physical damage, and ensuring the surrounding environment meets the specified operating conditions.