Imej mungkin representasi.
Lihat spesifikasi untuk butiran produk.
TPS3705-50DR

TPS3705-50DR

Product Overview

Category

The TPS3705-50DR belongs to the category of voltage supervisors.

Use

It is primarily used for monitoring and supervising voltage levels in electronic systems.

Characteristics

  • Voltage threshold: 5.0V
  • Supply voltage range: 1.8V to 18V
  • Low quiescent current: 3µA (typical)
  • Adjustable hysteresis
  • Open-drain output
  • Wide temperature range: -40°C to +125°C
  • Small package size: SOIC-8

Package and Quantity

The TPS3705-50DR is available in a small outline integrated circuit (SOIC) package with eight pins. It is typically sold in reels or tubes containing multiple units.

Specifications

  • Supply voltage range: 1.8V to 18V
  • Threshold voltage accuracy: ±1.5%
  • Quiescent current: 3µA (typical)
  • Operating temperature range: -40°C to +125°C
  • Output type: Open-drain
  • Power-on reset delay time: 20ms (typical)

Pin Configuration

The TPS3705-50DR has the following pin configuration:

```


| | --| VDD GND |-- Pin 1: Ground (GND) --| VIN RST |-- Pin 2: Reset (RST) --| VIT OUT |-- Pin 3: Output (OUT) --| VDD GND |-- Pin 4: Ground (GND) |___________| ```

Functional Features

  • Voltage monitoring: The TPS3705-50DR continuously monitors the input voltage and provides a reset signal when it falls below the specified threshold.
  • Adjustable hysteresis: The device allows the user to set the voltage threshold and hysteresis levels according to their specific requirements.
  • Open-drain output: The open-drain output provides flexibility in connecting to different systems and devices.
  • Low quiescent current: With a typical quiescent current of only 3µA, the TPS3705-50DR minimizes power consumption.

Advantages and Disadvantages

Advantages

  • Wide supply voltage range allows for compatibility with various electronic systems.
  • Adjustable hysteresis enables customization for different applications.
  • Low quiescent current reduces power consumption.
  • Small package size facilitates space-constrained designs.

Disadvantages

  • Lack of built-in overvoltage protection.
  • Limited output drive capability.

Working Principles

The TPS3705-50DR operates by comparing the input voltage (VIN) with the internally set threshold voltage. When VIN falls below the threshold, the reset output (RST) is activated, indicating a low-voltage condition. The reset remains active until VIN rises above the threshold voltage plus the hysteresis level.

Detailed Application Field Plans

The TPS3705-50DR finds application in various fields, including: 1. Power supply monitoring in industrial control systems. 2. Battery management systems in automotive electronics. 3. Overvoltage protection circuits in consumer electronics. 4. Voltage supervision in communication equipment. 5. Fault detection in medical devices.

Detailed and Complete Alternative Models

Some alternative models that offer similar functionality to the TPS3705-50DR include: - TPS3705-33DR: Threshold voltage of 3.3V. - TPS3705-25DR: Threshold voltage of 2.5V. - TPS3705-15DR: Threshold voltage of 1.5V.

These alternative models provide options for different voltage threshold requirements in voltage monitoring applications.

Word count: 413 words

Senaraikan 10 soalan dan jawapan biasa yang berkaitan dengan aplikasi TPS3705-50DR dalam penyelesaian teknikal

Sure! Here are 10 common questions and answers related to the application of TPS3705-50DR in technical solutions:

  1. Q: What is TPS3705-50DR? A: TPS3705-50DR is a voltage supervisor and reset IC manufactured by Texas Instruments.

  2. Q: What is the purpose of TPS3705-50DR? A: TPS3705-50DR is used to monitor the voltage level of a system and generate a reset signal when the voltage falls below a certain threshold.

  3. Q: What is the operating voltage range of TPS3705-50DR? A: TPS3705-50DR operates within a voltage range of 1.8V to 6.5V.

  4. Q: How does TPS3705-50DR ensure accurate voltage monitoring? A: TPS3705-50DR uses a precision voltage reference and comparator to accurately monitor the voltage level.

  5. Q: Can TPS3705-50DR be used in battery-powered applications? A: Yes, TPS3705-50DR can be used in battery-powered applications as it has low quiescent current consumption.

  6. Q: What is the typical reset threshold voltage of TPS3705-50DR? A: The typical reset threshold voltage of TPS3705-50DR is 4.55V.

  7. Q: Does TPS3705-50DR have an adjustable reset threshold? A: No, TPS3705-50DR has a fixed reset threshold voltage and does not offer adjustability.

  8. Q: Can TPS3705-50DR tolerate voltage transients or spikes? A: Yes, TPS3705-50DR has built-in hysteresis to tolerate voltage transients and spikes.

  9. Q: What is the output type of TPS3705-50DR? A: TPS3705-50DR has an open-drain output, which requires an external pull-up resistor.

  10. Q: Is TPS3705-50DR available in different package options? A: Yes, TPS3705-50DR is available in a small SOT-23 package for space-constrained applications.

Please note that these answers are general and may vary depending on the specific application and requirements.